4.4 Article

Thermal analysis, pressure drop and exergy loss of energy efficient shell, and triple meshed helical coil tube heat exchanger

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/15567036.2019.1602213

关键词

Energy efficient; exergy analysis; Nusselt number; pressure drop; triple meshed helical coil tube

向作者/读者索取更多资源

Majority of studies has been reported in literature in recent years on performance of shell and helical coil tube heat exchanger. The present work attempts to design and analyze experimentally hot water temperature difference, Nusselt number, Dean number, exergy loss, effectiveness and pressure drop in a shell, and triple meshed helical coil tube (TMHCT) heat exchanger. The effects of hot water flowing in TMHCT ranging from 1 to 3 L/min at different inlet temperatures (50 degrees C, 60 degrees C, 70 degrees C, 80 degrees C) and cold water flow in range of 1-3 L/min on shell side at constant inlet temperature 25 degrees C were investigated throughout the experiment. The results show that the heat transfer characteristics increase with increasing hot water volume flow rate and inlet temperature. It was also found that the performance enhancement of shell and TMHCT heat exchanger with least penalty of pressure drop was noticed as compared to existing shell and single helical coil tube heat exchanger.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据