4.7 Article

Thermal-hydraulic performances in multiple twisted tapes inserted sinusoidal rib tube heat exchangers for exhaust gas heat recovery applications

期刊

ENERGY CONVERSION AND MANAGEMENT
卷 185, 期 -, 页码 271-290

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2019.01.074

关键词

Heat transfer enhancement; Sinusoidal rib; Multiple twisted tapes; Multiple longitudinal vortexes; Swirl flow

资金

  1. Public Welfare Technological Research Program of Science and Technology Department of Zhejiang Province [2017C31127, LGG18E060003]
  2. Research Program of Science and Technology Bureau of Lishui City [2017RC03]
  3. Guangdong Provincial Key Laboratory of Distributed Energy Systems [2017DES02]

向作者/读者索取更多资源

The article presents a numerical investigation on turbulent thermal and fluid flow characteristics of multiple twisted tapes (MTTs) inserted sinusoidal rib tube (SRT) heat exchangers based on exhaust gas heat recovery background. The effects including geometric parameters of tape number (single, twin, triple and quadruple twisted tapes) and tape arrangements (clockwise and anticlockwise or co-swirl and counter-swirl) in the SRT were comparably studied. A periodic RNG k-epsilon numerical model was employed to depict the heat transfer behaviors and flow structures in the SRTs at a constant wall temperature condition. The results showed that the alone use of the SRT yielded enhanced heat transfer of about 27.4%-39.5% and increased friction loss of around 49.4%-74.7% higher than that in the baseline of spirally corrugated tube (SCT). In addition, it was found that the diverse thermo-hydraulic performances in the SRTs fitted with MTTs were dominated by flow structures of swirl flows and shear flows. By the synergy of longitudinal vortexes from SRT and MTTs, the Nusselt number and friction factor obtained from the SRTs fitted with MTTs were, respectively, larger than that from SCT at about 1.43-1.87 times and 2.66-10.07 times. In contrast to the SCT, the overall thermal performance evaluation criterion (PEC) was enhanced up to 1.59 for the alone use of SRT. Moreover, the PEC could be improved under increased heat transfer and reasonable pressure drop via suitable tape arrangements in the SRTs mounted with MTTs, of which the best PEC was 1.49. At last, the comparisons of present results with previous studies proved that the proposed enhanced devices held some competitive advantages.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据