4.6 Article

Plasma and dried blood spot lysosphingolipids for the diagnosis of different sphingolipidoses: a comparative study

期刊

CLINICAL CHEMISTRY AND LABORATORY MEDICINE
卷 57, 期 12, 页码 1863-1874

出版社

WALTER DE GRUYTER GMBH
DOI: 10.1515/cclm-2018-1301

关键词

biomarkers; dried blood spot (DBS); Fabry disease; gangliosidosis GM1; gangliosidosis GM2; Gaucher disease; Krabbe disease; Niemann-Pick type A/B disease; Niemann-Pick type C disease

资金

  1. Associazione COMETA-ASMME (Associazione Studio Malattie Metaboliche Ereditarie)

向作者/读者索取更多资源

Background: Lysosphingolipids, the N-deacylated forms of sphingolipids, have been identified as potential biomarkers of several sphingolipidoses, such as Gaucher, Fabry, Krabbe and Niemann-Pick diseases and in GM1 and GM2 gangliosidoses. To date, different methods have been developed to measure various lysosphingolipids (LysoSLs) in plasma. Here, we present a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for a simultaneous quantification of LysoSLs (HexSph, LysoGb3, LysoGM1, LysoGM2, LysoSM and LysoSM509) in dried blood spot (DBS). This LC-MS/MS method was used to compare the levels of LysoSLs in DBS and plasma in both affected patients and healthy controls. Methods: Lysosphingolipids were extracted from a 3.2 mm diameter DBS with amixture of methanol:acetonitrile:water (80:15:5, v/v) containing internal stable isotope standards. Chromatographic separation was performed using a C18 column with a gradient of water and acetonitrile both with 0.1% formic acid in a total run time of 4 min. The-compounds were detected in the positive ion mode electrospray ionization (ESI)-MS/MS by multiple reaction monitoring (MRM). Results: The method was validated on DBS to demonstrate specificity, linearity, lowest limit of quantification, accuracy and precision. The reference ranges were determined in pediatric and adult populations. The elevated levels of LysoSLs were identified in Gaucher disease (HexSph), Fabry disease (LysoGb3), prosaposin deficiency (HexSph and LysoGb3) and Niemann-Pick disease types A/B and C (LysoSM and LysoSM509). The correlation in the levels between DBS and plasma was excellent for LysoGb3 and HexSph but poor for LysoSM and LysoSM509. Conclusions: Despite the fact that plasma LysoSLs determination remains the gold standard, our LC-MS/MS method allows a rapid and reliable quantification of lysosphingolipids in DBS. The method is a useful tool for the diagnosis of different sphingolipidoses except for -Niemann-Pick type C.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据