This paper presents an experimental investigation on variations of evaporating temperature (t(e)) with different configuration parameters, including the nozzle throat diameter of ejector (D-t) and the capillary tube length (L-c), in an ejector-expansion refrigeration cycle (ERC) system. In addition, effects of refrigerant charge amount (CA) have been investigated at the different D-t and L-c based on the ERC system. The results show that a reasonable matching between CA and D-t or between CA and L-c can adjust the t(e) while maintaining the mass flow rate of the fluid through the evaporator within an appropriate range. Furthermore, the effects of D-t and L-c on the ejector performances at the different CA have been studied. The results show that the performances of ejector are strongly affected by these parameters. The meaningful results obtained here may serve as good guidelines for developing the ejector expansion refrigeration technologies applied in practical refrigeration systems.