期刊
ANALYTICAL CHEMISTRY
卷 91, 期 9, 页码 6383-6390出版社
AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.9b01506
关键词
-
资金
- National Institute for Medical Research Development (NIMAD) [957699]
A sensitive prostate-specific antigen (PSA) detection method using a visual-readout closed bipolar electrode (BPE) system has been introduced by integration of hydrogen evolution reaction (HER) in cathodic pole and electrochemiluminescence (ECL) of luminol loaded within the MIL-53(Fe)-NH2 (L@MIL-53(Fe)-NH2) in the anodic pole. The cathode of the BPE was electrochemically synthesized by 3D porous copper foam, followed by decorating with nitrogen-doped graphene nanosheet and ruthenium nanoparticles. As an alternative, we employed carboxylate-modified magnetic nano particles (MNPs) for immobilization of the primary antibody (Ab1) and utilized the L@MIL-53(Fe)-NH2 conjugated to secondary antibody (Ab2) as a signaling probe and coreaction accelerator. After sandwiching the target PSA between Ab 1 and Ab2, the MNP/Ab1-PSA-Ab2/L@MIL-53(Fe) were introduced to a gold anodic BPE. Finally, the resulting ECL of luminol and H2O2 at the anodic poles was monitored using a photomultiplier tube (PMT) or digital camera. The PMT and visual (camera)-based detections showed linear responses from 1 pg mL(-1) to 300 ng mL(-1) (limit of detection 0.2 pg mL(-1)) and 5 pg mL(-1) to 200 rig mL(-1) (limit of detection 0.1 pg mL(-1)), respectively. This strategy provides an effective method for high-performance bioanalysis and opens a new door toward the development of the highly sensitive and user-friendly device.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐