4.7 Article

Quantitative measurement of selected protein biomarkers of endothelial dysfunction in plasma by micro-liquid chromatography-tandem mass spectrometry based on stable isotope dilution method

期刊

TALANTA
卷 194, 期 -, 页码 1005-1016

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2018.10.067

关键词

Endothelium; Biomarkers; Targeted proteomics; MicroLC/MS-MRM; SID; Mice

资金

  1. National Centre for Research and Development, Warsaw, Poland
  2. Jagiellonian Centre for Experimental Therapeutics (JCET
  3. UJ), Krakow, Poland [STRATEGMED1/233226/11/NCBR/2015]
  4. Jagiellonian University Medical College (UJ CM), Krakow, Poland [K/ZDS/006223]

向作者/读者索取更多资源

The aim of this study was to develop and validate the novel microLC/MS-MRM method for the simultaneous quantification of six proteins: angiopoietin 2 (Angpt-2), soluble form of fms-like tyrosine kinase 1 (sFLT-1), plasminogen activator inhibitor 1 (PAI-1), tissue plasminogen activator (t-PA), endocan (ESM-1), soluble form of E-selectin (sE-sel), and one peptide: adrenomedullin (ADM) in mouse plasma. Two approaches were compared: a stable isotope dilution (SID) method- used as a reference and a modified SID (mSID) procedure. In SID strategy the calibration curves were used, whereas in mSID the ratio between the chromatogram peak area of endogenous tryptic peptides at unknown concentration to chromatogram peak area of exogenous, stable isotope-labelled internal standards (SISs) added to the sample at known concentration was calculated. The microLC/MS-MRM method in the SID approach was linear from 0.250 pmol/mL to 250 pmol/mL for Angpt-2; 5 pmol/mL to 5000 pmol/mL for sFLT-1; 2.5 pmol/mL to 5000 pmol/mL for PAI-1; 0.375 pmol/mL to 250 pmol/mL for t-PA; 0.375 pmol/mL to 187.5 pmol/mL for ESM-1; 2.5 pmol/mL to 5000 pmol/mL for sE-sel and 0.375 pmol/mL to 250 pmol/mL for ADM. LPS-induced changes in plasma assessed based on SID and mSID approaches gave comparable quantitative results and featured LPS-induced dysregulation of endothelial permeability (Angpt-2, sFLT-1), glycocalyx injury (SDC-1) accompanied by a pro-thrombotic response (PAI-1). In addition, we applied microLC/MS-MRM method with mSID strategy to analyze human plasma samples from patients with chronic myeloid leukemia (CML) and obstructive sleep apnoea (OSA) and demonstrated usefulness of the method to characterize endothelial function in humans. In conclusion, the microLC/MS-MRM method with mSID strategy applied for simultaneous quantification of protein biomarkers of endothelial function in plasma represents a novel targeted proteomic platform for the comprehensive evaluation of endothelial function in mice and humans.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据