4.7 Article

Sensing corrosion within an artificial defect in organic coating using SECM

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 280, 期 -, 页码 235-242

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2018.10.051

关键词

Electrochemical noise; Corrosion; Scanning electrochemical microscopy (SECM); Power spectral density (PSD)

资金

  1. National Natural Science Foundation of China [51701140]
  2. CAS Key laboratory of Nuclear Materials and Safety Assessment (Institute of Metal Research, Chinese Academy of Sciences, China) [2018NMSAKF01]

向作者/读者索取更多资源

The electrochemical reactivity of a defect in organic coating was investigated by electrochemical noise (EN) and scanning electrochemical microscopy (SECM). Time dependent EN spectra and SECM image on a metal with defective organic coating was measured, and corresponding EN frequency domain spectra and probe approach curves (PACs) were used to obtain electrochemical reactivity information within the coating defects. All time domain and frequency domain analyses, and SECM measurements were successful indicators of corrosion intensity within the defect. The amplitude of electrochemical current noise (ECN) and the low-frequency plateau of the power spectral density (PSD) W-L increased significantly with corrosion intensity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据