4.7 Article

Use of Elastic Registration in Pulmonary MRI for the Assessment of Pulmonary Fibrosis in Patients with Systemic Sclerosis

期刊

RADIOLOGY
卷 291, 期 2, 页码 486-491

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2019182099

关键词

-

向作者/读者索取更多资源

Background: Current imaging methods are not sensitive to changes in pulmonary function resulting from fibrosis. MRI with ultrashort echo time can be used to image the lung parenchyma and lung motion. Purpose: To evaluate elastic registration of inspiratory-to-expiratory lung MRI for the assessment of pulmonary fibrosis in study participants with systemic sclerosis (SSc). Materials and Methods: This prospective study was performed from September 2017 to March 2018 and recruited healthy volunteers and participants with SSc and high-resolution CT (within the previous 3 months) of the chest for lung MRI. Two breathhold, coronal, three-dimensional, ultrashort-echo-time, gradient-echo sequences of the lungs were acquired after full inspiration and expiration with a 3.0-T unit. Images were registered from inspiration to expiration by using an elastic registration algorithm. Jacobian determinants were calculated from deformation fields and represented on color maps. Similarity between areas with marked shrinkage and logarithm of Jacobian determinants less than 20.15 were compared between healthy volunteers and study participants with SSc. Receiver operating characteristic curve analysis was performed to determine the best Dice similarity coefficient threshold for diagnosis of fibrosis. Results: Sixteen participants with SSc (seven with pulmonary fibrosis at high-resolution CT) and 11 healthy volunteers were evaluated. Areas of marked shrinkage during expiration with logarithm of Jacobian determinants less than 20.15 were found in the posterior lung bases of healthy volunteers and in participants with SSc without fibrosis, but not in participants with fibrosis. The sensitivity and specificity of MRI for presence of fibrosis at high-resolution CT were 86% and 75%, respectively (area under the curve, 0.81; P =.04) by using a threshold of 0.36 for Dice similarity coefficient. Conclusion: Elastic registration of inspiratory-to-expiratory MRI shows less lung base respiratory deformation in study participants with systemic sclerosis-related pulmonary fibrosis compared with participants without fibrosis. (c) RSNA, 2019

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据