Joint correction of attenuation and scatter in image space using deep convolutional neural networks for dedicated brain 18F-FDG PET

期刊

PHYSICS IN MEDICINE AND BIOLOGY
卷 64, 期 7, 页码 -

出版社

IOP PUBLISHING LTD
DOI: 10.1088/1361-6560/ab0606

关键词

brain FDG PET; attenuation correction; scatter correction; convolutional neural network; deep learning

资金

  1. National Institutes of Health [R01HL135490, R01EB026331]

向作者/读者索取更多资源

Dedicated brain positron emission tomography (PET) devices can provide higher-resolution images with much lower doses compared to conventional whole-body PET systems, which is important to support PET neuroimaging and particularly useful for the diagnosis of neurodegenerative diseases. However, when a dedicated brain PET scanner does not come with a combined CT or transmission source, there is no direct solution for accurate attenuation and scatter correction, both of which are critical for quantitative PET. To address this problem, we propose joint attenuation and scatter correction (ASC) in image space for non-corrected PET (PETNC) using deep convolutional neural networks (DCNNs). This approach is a one-step process, distinct from conventional methods that rely on generating attenuation maps first that are then applied to iterative scatter simulation in sinogram space. For training and validation, time-of-flight PET/MR scans and additional helical CTs were performed for 35 subjects (25/10 split for training and test dataset). A DCNN model was proposed and trained to convert PETNC to DCNN -based ASC PET (PETDCNN) directly in image space. For quantitative evaluation, uptake differences between PETDCNN and reference CT-based ASC PET (PETCT-ASC) were computed for 116 automated anatomical labels (AALs) across 10 test subjects (1160 regions in total). MR-based ASC PET (PETMR-ASC), a current clinical protocol in PET/MR imaging, was another reference for comparison. Statistical significance was assessed using a paired t test. The performance of PETDCNN was comparable to that of PETMR-ASC, in comparison to reference PETCT-ASC. The mean SUV differences (mean +/- SD) from PETCT-ASC were 4.0% +/- 15.4% (P < 0.001) and -4.2% +/- 4.3% (P < 0.001) for PETDCNN and PETMR-ASC, respectively. The overall larger variation of PETDCNN (1 5.4%) was prone to the subject with the highest mean difference (48.5% +/- 10.4%). The mean difference of PETDCNN excluding the subject was substantially improved to -0.8% +/- 5.2% (P < 0.001), which was lower than that of PETMR-ASC ( - 5.07% +/- 3.60%, P < 0.001). In conclusion, we demonstrated the feasibility of directly producing PET images corrected for attenuation and scatter using a DCNN (PETDCNN) from PETNC in image space without requiring conventional attenuation map generation and time-consuming scatter correction. Additionally, our DCNN -based method provides a possible alternative to MR-ASC for simultaneous PET/MRI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据