4.7 Article

Accurate vessel extraction via tensor completion of background layer in X-ray coronary angiograms

期刊

PATTERN RECOGNITION
卷 87, 期 -, 页码 38-54

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.patcog.2018.09.015

关键词

X-ray coronary angiography; Tensor completion; Robust principal component analysis; Vessel segmentation; Layer separation; Vessel enhancement; Vessel recovery

资金

  1. National Natural Science Foundation of China [61271320, 61362001, 81371634, 81370041, 81400261, 61503176]
  2. National Key Research and Development Program of China [2016YFC1301203, 2016YFC0104608]
  3. Shanghai Jiao Tong University Medical Engineering Cross Research Funds [YG2017ZD10, YG2016MS45, YG2015ZD04, YG2014MS29, YG2014ZD05]
  4. young scientist training plan of Jiangxi province [20162BCB23019]
  5. three-year plan program by Shanghai Shen Kang Hospital Development Center [16CR3043A]
  6. NIH [R01CA156775, R21CA176684, R01CA204254, R01HL140325]

向作者/读者索取更多资源

This paper proposes an effective method for accurately recovering vessel structures and intensity information from the X-ray coronary angiography (XCA) images of moving organs or tissues. Specifically, a global logarithm transformation of XCA images is implemented to fit the X-ray attenuation sum model of vessel/background layers into a low-rank, sparse decomposition model for vessel/background separation. The contrast-filled vessel structures are extracted by distinguishing the vessels from the low rank backgrounds by using a robust principal component analysis and by constructing a vessel mask via Radon-like feature filtering plus spatially adaptive thresholding. Subsequently, the low-rankness and inter-frame spatio-temporal connectivity in the complex and noisy backgrounds are used to recover the vessel-masked background regions using tensor completion of all other background regions, while the twist tensor nuclear norm is minimized to complete the background layers. Finally, the method is able to accurately extract vessels' intensities from the noisy XCA data by subtracting the completed background layers from the overall XCA images. We evaluated the vessel visibility of resulting images on real X-ray angiography data and evaluated the accuracy of vessel intensity recovery on synthetic data. Experiment results show the superiority of the proposed method over the state-of-the-art methods. (C) 2018 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据