4.8 Article

Microelectrode Arrays of Diamond-Insulated Graphitic Channels for Real-Time Detection of Exocytotic Events from Cultured Chromaffin Cells and Slices of Adrenal Glands

期刊

ANALYTICAL CHEMISTRY
卷 88, 期 15, 页码 7493-7499

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.5b04449

关键词

-

资金

  1. Italian National Institute of Nuclear Physics [157660]
  2. FIRB Futuro in Ricerca Project - Italian Ministry for Teaching, University and Research (MIUR) [D11J11000450001]
  3. A.Di.N-Tech. Project - University of Torino [D15E13000130003]
  4. Compagnia di San Paolo
  5. Italian MIUR [2010JFYFY2]
  6. Torino University

向作者/读者索取更多资源

A microstructured graphitic 4 x 4 multi electrode array was embedded in a single-crystal diamond substrate (4 x 4 mu G-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time-effective fabrication of extended arrays, with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20 x 3.5 mu m(2)) separated by 200 mu m gaps. Taking advantage of the array geometry we addressed the following specific issues: (0 detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, (ii) resolve the waveform of different subsets of exocytotic events, and (iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 and 0.3 Hz, respectively, for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated with full fusion events, kiss-and-run and kiss-and-stay exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据