4.3 Article

Method for analysis of ClO2 and Cl2 air emissions from pulp mill

期刊

NORDIC PULP & PAPER RESEARCH JOURNAL
卷 34, 期 1, 页码 19-27

出版社

AB SVENSK PAPPERSTIDNING
DOI: 10.1515/npprj-2018-0012

关键词

analytical method; bleaching; chlorine; chlorine dioxide; emissions; field study; pulp mill

向作者/读者索取更多资源

Chlorine dioxide is commonly used as a bleaching agent in kraft pulp mills. Scrubbers are required to remove any remaining ClO(2 )from the plant tail gases. To control the air emissions of chlorine compounds, chlorine dioxide and chlorine contents must be monitored to ensure that the strict regulatory standards are met. However, the currently used analytical method is not suitable for detection of low concentrations of chlorine and chlorine dioxide. A new method for measuring chlorine dioxide and chlorine emissions was developed, which ensures compliance with the stringent requirements imposed by the authorities. The two species could be measured separately with a limit of quantification of 3 ppm. The method was robust and easy to use in the pulp mill environment and it was validated both in the laboratory and the field. The specificity of the method was demonstrated, Cl-2 analysis was not sensitive to the presence of ClO2 and vice versa. The uncertainty (+/- 2xRSD) of the analytical method in the field was estimated from duplicate measurements performed in the range of 3-500 ppm for ClO2 and 3-300 ppm for Cl-2, and was found to be +/- 20 % and +/- 10%, respectively. Possible interferences in the analytical method are also discussed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据