METROLOGIA
卷 56, 期 3, 页码 -出版社
IOP PUBLISHING LTD
DOI: 10.1088/1681-7575/ab0dbe
关键词
thermometry; thermodynamic temperature; refractive index; microwave resonators; polarizability; virial coefficients
资金
- National Key R&D Program of China [2016YFE0204200]
The principles and techniques of primary refractive-index gas thermometry (RIGT) are reviewed. Absolute primary RIGT using microwave measurements of helium-filled quasi-spherical resonators has been implemented at the temperatures of the triple points of neon, oxygen, argon and water, with relative standard uncertainties ranging from 9.1 x 10(-6) to 3.5 x 10(-5). Researchers are now also using argon-filled cylindrical microwave resonators for RIGT near ambient temperature, with relative standard uncertainties between 3.8 x 10(-5) and 4.6 x 10(-5), and conducting relative RIGT measurements on isobars at low temperatures. RIGT at optical frequencies is progressing, and has been used to perform a Boltzmann constant measurement at room temperature with a relative standard uncertainty of 1.2 x 10(-5). Uncertainty budgets from implementations of absolute primary microwave RIGT, relative primary microwave RIGT and absolute primary optical RIGT are provided.