4.6 Article

U-Net based deep learning bladder segmentation in CT urography

期刊

MEDICAL PHYSICS
卷 46, 期 4, 页码 1752-1765

出版社

WILEY
DOI: 10.1002/mp.13438

关键词

bladder; computer-aided detection; CT urography; deep learning; segmentation

资金

  1. NIH [U01CA179106]
  2. China Department of Science and Technology Key grant [2016YFB0200602]
  3. NSFC [81830052, 11401601]
  4. Science and Technology Innovative Project of Guangdong Province, China [2016B030307003, 2015B010110003, 2015B020233008]
  5. Guangdong Provincial Science and Technology Key Grant [2017B020210001]
  6. Guangzhou Science and Technology Creative Key Grant [201604020003]

向作者/读者索取更多资源

ObjectivesTo develop a U-Net-based deep learning approach (U-DL) for bladder segmentation in computed tomography urography (CTU) as a part of a computer-assisted bladder cancer detection and treatment response assessment pipeline. Materials and methodsA dataset of 173 cases including 81 cases in the training/validation set (42 masses, 21 with wall thickening, 18 normal bladders), and 92 cases in the test set (43 masses, 36 with wall thickening, 13 normal bladders) were used with Institutional Review Board approval. An experienced radiologist provided three-dimensional (3D) hand outlines for all cases as the reference standard. We previously developed a bladder segmentation method that used a deep learning convolution neural network and level sets (DCNN-LS) within a user-input bounding box. However, some cases with poor image quality or with advanced bladder cancer spreading into the neighboring organs caused inaccurate segmentation. We have newly developed an automated U-DL method to estimate a likelihood map of the bladder in CTU. The U-DL did not require a user-input box and the level sets for postprocessing. To identify the best model for this task, we compared the following models: (a) two-dimensional (2D) U-DL and 3D U-DL using 2D CT slices and 3D CT volumes, respectively, as input, (b) U-DLs using CT images of different resolutions as input, and (c) U-DLs with and without automated cropping of the bladder as an image preprocessing step. The segmentation accuracy relative to the reference standard was quantified by six measures: average volume intersection ratio (AVI), average percent volume error (AVE), average absolute volume error (AAVE), average minimum distance (AMD), average Hausdorff distance (AHD), and the average Jaccard index (AJI). As a baseline, the results from our previous DCNN-LS method were used. ResultsIn the test set, the best 2D U-DL model achieved AVI, AVE, AAVE, AMD, AHD, and AJI values of 93.49.5%, -4.2 +/- 14.2%, 9.2 +/- 11.5%, 2.7 +/- 2.5mm, 9.7 +/- 7.6mm, 85.0 +/- 11.3%, respectively, while the corresponding measures by the best 3D U-DL were 90.6 +/- 11.9%, -2.3 +/- 21.7%, 11.5 +/- 18.5%, 3.1 +/- 3.2mm, 11.4 +/- 10.0mm, and 82.6 +/- 14.2%, respectively. For comparison, the corresponding values obtained with the baseline method were 81.9 +/- 12.1%, 10.2 +/- 16.2%, 14.0 +/- 13.0%, 3.6 +/- 2.0mm, 12.8 +/- 6.1mm, and 76.2 +/- 11.8%, respectively, for the same test set. The improvement for all measures between the best U-DL and the DCNN-LS were statistically significant (P<0.001). ConclusionCompared to a previous DCNN-LS method, which depended on a user-input bounding box, the U-DL provided more accurate bladder segmentation and was more automated than the previous approach.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据