4.7 Article

Measuring the temperature of a rapidly evaporating water droplet by Planar Laser Induced Fluorescence

期刊

MEASUREMENT
卷 135, 期 -, 页码 231-243

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.measurement.2018.11.047

关键词

Planar Laser Induced Fluorescence; Rhodamine B fluorophore; Calibration; Evaporating water droplet; Temperature field; Temperature profile

资金

  1. National Research Tomsk Polytechnic University [VIU-ISHFVP-184/2018]

向作者/读者索取更多资源

In this paper, we present the experimental research into the unsteady temperature fields of an evaporating water droplet with a 1-2 mm initial radius attached to a holder in a flow of air heated up to 1,000 degrees C. The limitations of Planar Laser Induced Fluorescence are established. We identify four distinct stages of droplet evaporation, in which the use and calibration of Planar Laser Induced Fluorescence differ significantly. Changes in the dye concentration in the droplet are found to result from the dye evaporation from the free surface of the droplet and its sedimentation onto the holder. A correction factor is introduced, based on the experimental results and dependent on a number of effects discussed. The factor is used to adjust the experimental measurements made via Planar Laser Induced Fluorescence and to obtain the reliable temperature fields of a rapidly evaporating water droplet. (C) 2018 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据