4.4 Article

Transcutaneous transmission of photobiomodulation light to the spinal canal of dog as measured from cadaver dogs using a multi-channel intra-spinal probe

期刊

LASERS IN MEDICAL SCIENCE
卷 34, 期 8, 页码 1645-1654

出版社

SPRINGER LONDON LTD
DOI: 10.1007/s10103-019-02761-0

关键词

Photobiomodulation; Low-level light therapy; 980 nm; Dosimetry; Spinal cord injury; Transcutaneous

资金

  1. LiteCure LLC

向作者/读者索取更多资源

The target level photobiomodulation (PBM) irradiances along the thoracic to lumbar segment of the interior spinal canal in six cadaver dogs resulting from surface illumination at 980 nm were measured. Following a lateral hemi-laminectomy, a flexible probe fabricated on a plastic tubular substrate of 6.325 mm diameter incorporating nine miniature photodetectors was embedded in the thoracic to lumbar segment of the spinal canal. Intra-spinal irradiances at the nine photodetector sites, spanning an approximate 8 cm length caudal to T13, were measured for various applied powers of continuous wave (CW) surface illumination at 980 nm with a maximal power of 10 W corresponding to a surface irradiance of 3.14 W/cm2. The surface illumination conditions differed in skin transmission when the probe was off-contact with tissue and probe-skin contact when the skin was in place. For each condition of surface illumination, the beam was directed to respectively T13 (surface site 1), a spinal column site 4 cm caudal to T13 (surface site 5), and a spinal column site 8 cm caudal to T13 (surface site 9). Off-contact surface irradiation of 3.14 W/cm2 at surface sites 1, 5, and 9 transmitted respectively 234.0 +/- 120.7 mu W/cm2, 230.7 +/- 178.3 mu W/cm2, and 130.2 +/- 169.6 mu W/cm2 to the spinal canal without the skin, and respectively 35.7 +/- 33.2 mu W/cm2, 50.9 +/- 75.3 mu W/cm2, and 15.7 +/- 16.3 mu W/cm2 with the skin. Transmission with skin was as low as 12% of the transmission without the skin. On-contact surface irradiation of 3.14 W/cm2 at surface sites 1, 5, and 9 transmitted respectively 44.6 +/- 43.1 mu W/cm2, 85.4 +/- 139.1 mu W/cm2, and 22.0 +/- 23.6 mu W/cm2 to the spinal canal. On-contact application increased transmission by a maximum of 67% comparing to offcontact application. The information gathered highlights the need to clinically consider the impact of skin transmission and oncontact application technique when attempting to treat spinal cord disease with PBM.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据