4.7 Article

External calibration strategy for trace element quantification in botanical samples by LA-ICP-MS using filter paper

期刊

ANALYTICA CHIMICA ACTA
卷 905, 期 -, 页码 51-57

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2015.11.049

关键词

Laser ablation; Inductively coupled plasma-mass spectrometry; Plant samples; Calibration

资金

  1. CNPq [308745/2013-2]
  2. CAPES
  3. FAPERGS

向作者/读者索取更多资源

The use of reference solutions dispersed on filter paper discs is proposed for the first time as an external calibration strategy for matrix matching and determination of As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sr, V and Zn in plants by laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS). The procedure is based on the use of filter paper discs as support for aqueous reference solutions, which are further evaporated, resulting in solid standards with concentrations up to 250 mu g g(-1) of each element. The use of filter paper for calibration is proposed as matrix matched standards due to the similarities of this material with botanical samples, regarding to carbon concentration and its distribution through both matrices. These characteristics allowed the use of C-13 as internal standard (IS) during the analysis by LA-ICP-MS. In this way, parameters as analyte signal normalization with C-13, carrier gas flow rate, laser energy, spot size, and calibration range were monitored. The calibration procedure using solution deposition on filter paper discs resulted in precision improvement when C-13 was used as IS. The method precisionwas calculated by the analysis of a certified reference material (CRM) of botanical matrix, considering the RSD obtained for 5 line scans and was lower than 20%. Accuracy of LA-ICP-MS determinations were evaluated by analysis of four CRM pellets of botanical composition, as well as by comparison with results obtained by ICP-MS using solution nebulization after microwave assisted digestion. Plant samples of unknown elemental composition were analyzed by the proposed LA method and good agreement were obtained with results of solution analysis. Limits of detection (LOD) established for LA-ICP-MS were obtained by the ablation of 10 lines on the filter paper disc containing 40 mL of 5% HNO3 (v v(-1)) as calibration blank. Values ranged from 0.05 to 0.81 mg g(-1). Overall, the use of filter paper as support for dried aqueous standards showed to be a useful strategy for calibration and plant analysis by LA-ICP-MS. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据