4.7 Article

Development of a microfluidic paper-based analytical device for the determination of salivary aldehydes

期刊

ANALYTICA CHIMICA ACTA
卷 919, 期 -, 页码 47-54

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2016.03.030

关键词

Aldehydes; Saliva; Microfluidic paper-based analytical device (mu PAD); 3-methyl-2-benzothiazolinone hydrazone (MBTH); Wax printing

向作者/读者索取更多资源

A low cost, disposable and easy to use microfluidic paper-based analytical device (mu PAD) was developed for simple and non-invasive determination of total aldehydes in saliva with a potential to be used in epidemiological studies to assess oral cancer risk. The mu PAD is based on the colour reaction between aldehydes (e.g. acetaldehyde, formaldehyde), 3-methyl-2-benzothiazolinone hydrazone (MBTH) and iron(III) to form an intense blue coloured formazan dye. The newly developed mu PAD has a 3D design with two overlapping paper layers. The first layer comprises 15 circular detection zones (8 mm in diameter), each impregnated with 8 mL of MBTH, while the second layer contains 15 reagent zones (4 mm in diameter). Two mL of iron(III) chloride are added to each one of the second layer zones after the addition of sample to the detection zones in the first layer. All hydrophilic zones of the mu PAD are defined by wax printing using a commercial wax printer. Due to the 2-step nature of the analytical reaction, the two paper layers are separated by a cellulose acetate interleaving sheet to allow for the reaction between the aldehydes in the saliva sample with MBTH to proceed first with the formation of an azine, followed by a blue coloured reaction between the azine and the oxidized by iron(III) form of MBTH, produced after the removal of the interleaving sheet. After obtaining a high resolution image of the detection side zone of the device using a flatbed scanner, the intensity of the blue colour within each detection zone is measured with Image J software. Under optimal conditions, the mPAD is characterised by a working range of 20.4-114.0 mu M, limit of detection of 6.1 mu M, and repeatability, expressed as RSD, of less than 12.7% (n = 5). There is no statistically significant difference at the 95% confidence level between the results obtained by the mu PAD and the reference method (Student's t-test: 0.090 < 0.38). The optimized mu PAD is stable for more than 41 days when stored in a freezer (<=-20 degrees C). (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据