4.5 Article

Endoscopic Hemostasis in Porcine Gastrointestinal Tract Using CO2 Low-Temperature Plasma Jet

期刊

JOURNAL OF SURGICAL RESEARCH
卷 234, 期 -, 页码 334-342

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jss.2018.09.068

关键词

Low temperature plasma; Blood coagulation; Gastrointestinal bleeding; Endoscope; 3D printer

类别

资金

  1. Cooperative Research Project of Research Center for Biomedical Engineering, Ministry of Education, Culture, Sports, Science and Technology, Japan
  2. Program for Creating Start-ups from Advanced Research and Technology, Japan [924083]
  3. Plasma Concept Tokyo, Inc.
  4. [16K17536]

向作者/读者索取更多资源

Background: Recently, atmospheric low-temperature plasma (LTP) has attracted attention as a novel medical tool that might be useful for achieving hemostasis. However, conventional plasma sources are too big for use with endoscopes, and the efficacy of LTP for achieving hemostasis in cases of gastrointestinal bleeding is difficult to investigate. In this study, to solve the problem, we developed a 3D-printed LTP jet that has a diameter of 2.8 mm and metal body for endoscopic use. The characteristics, hemostasis efficacy, and safety were investigated. Materials and methods: On investigating the basic characteristics of the developed plasma jet, the electron densities, gas temperatures, and reactive species were measured by emission spectroscopy and thermocouple. To evaluate the efficacy of such hemostatic treatment, porcine gastrointestinal bleeding was treated with the device. In addition, to investigate the safety of such treatment, the CO2 LTP-treated tissue was compared with tissue that was treated with clipping-based or argon plasma coagulation-based hemostasis for 5 d, and hematoxylin and eosin staining was used to evaluate tissue damage in the treated regions. Results: The measurement of emission spectroscopy, power, and electron density of various gas plasmas suggested that a high-density (10(14) cm(-3)) LTP of CO2 was generated by the LTP jet, and the gas temperature was 41.5 degrees C at 3 mm from the outlet of the LTP jet. The CO2 LTP achieved hemostasis of oozing blood by 70 +/- 20 s. In addition, the CO2 LTP resulted in earlier recovery than clipping-based or argon plasma coagulation-based hemostases, and the treated regions had no damage by the CO2 LTP treatment. Conclusions: These results indicated that the developed LTP plasma jet has the potential to be used for endoscopic hemostasis. (C) 2018 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据