4.7 Article

Magnetization transfer saturation imaging of human calf muscle: Reproducibility and sensitivity to regional and sex differences

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 50, 期 4, 页码 1227-1237

出版社

WILEY
DOI: 10.1002/jmri.26694

关键词

magnetization transfer saturation imaging; calf muscle; sex differences; intermuscular differences

资金

  1. California State University Program for Education and Research in Biotechnology (CSUPERB)

向作者/读者索取更多资源

Background Magnetization transfer saturation (MTsat) derives a semiquantitative index of magnetization transfer in faster acquisition times than quantitative magnetization transfer; the potential of MTsat for muscle imaging has not yet been explored. Purpose To evaluate the potential of MTsat to identify regional and sex differences in calf muscle. Study Type Prospective cohort study. Phantom/Subjects Vials with different agar and nickel nitrate concentrations providing a range of macromolecular fraction and T-1. Seven male subjects (25 +/- 7 years) and seven female subjects (28 +/- 14 years); three subjects were scanned in three separate sessions to assess reproducibility. Field Strength/Sequence 3T, 3D fast low angle shot (FLASH) sequence with and without a magnetization transfer pulse; acquisition time of 4.12 minutes. Assessment The effectiveness of two methods of fat suppression was evaluated using the fat unsuppressed sequence as the reference and MTsat maps derived with and without transmit field inhomogeneity corrections were compared. Statistical evaluation of MTsat differences between calf muscles and between male and female cohorts was made. Statistical Tests Bland-Altman plots were used to assess fat suppression and B1+ correction. The coefficient of variation (CV) and the repeatability coefficient (RC) were calculated from the repeat sessions. Sex and regional differences were assessed using two-way factorial analyses of variance (ANOVAs) with Bonferroni-adjusted independent sample t-tests for post-hoc analyses. Results In phantoms, MTsat increased linearly with agar concentration and MTsat was independent of T-1 (P = 0.229) evaluated in phantoms with two T(1)s. The CV and RC of MTsat ranged between 2.65 to 5.03% and 0.13 to 0.38, respectively, in the different calf muscles. MTsat of the tibialis anterior was significantly higher than other muscles (P < 0.05). MTsat in male subjects was significantly higher than in female subjects (P = 0.009). Data Conclusion MTsat maps of calf muscle acquired under 5 minutes may have the potential to detect regional and sex differences. Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1227-1237.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据