4.7 Article

Optimization and repeatability of multipool chemical exchange saturation transfer MRI of the prostate at 3.0 T

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 50, 期 4, 页码 1238-1250

出版社

WILEY
DOI: 10.1002/jmri.26690

关键词

CEST; prostate; repeatability; optimization; cancer

资金

  1. Cancer Research UK (CRUK)
  2. Engineering and Physical Sciences Research Council (EPSRC) via the Comprehensive Cancer Imaging Centre (CCIC)
  3. National Institute for Health Research University College London Hospitals Biomedical Research Centre
  4. European Union [667510]

向作者/读者索取更多资源

Background Chemical exchange saturation transfer (CEST) can potentially support cancer imaging with metabolically derived information. Multiparametric prostate MRI has improved diagnosis but may benefit from additional information to reduce the need for biopsies. Purpose To optimize an acquisition and postprocessing protocol for 3.0 T multipool CEST analysis of prostate data and evaluate the repeatability of the technique. Study Type Prospective. Subjects Five healthy volunteers (age range: 24-47 years; median age: 28 years) underwent two sessions (interval range: 7-27 days; median interval: 20 days) and two biopsy-proven prostate cancer patients were evaluated once. Patient 1 (71 years) had a Gleason 3 + 4 transition zone (TZ) tumor and patient 2 (55 years) had a Gleason 4 + 3 peripheral zone (PZ) tumor. Field Strength 3.0 T. Sequences run: T-2-weighted turbo-spin-echo (TSE); diffusion-weighted imaging; CEST; WASABI (for B-0 determination). Assessment Saturation, readout, and fit-model parameters were optimized to maximize in vivo amide and nuclear Overhauser effect (NOE) signals. Repeatability (intrasession and intersession) was evaluated in healthy volunteers. Subsequently, preliminary evaluation of signal differences was made in patients. Regions of interest were drawn by two post-FRCR board-certified readers, both with over 5 years of experience in multiparametric prostate MRI. Statistical Tests Repeatability was assessed using Bland-Altman analysis, coefficient of variation (CV), and 95% limits of agreement (LOA). Statistical significance of CEST contrast was calculated using a nonparametric Mann-Whitney U-test. Results The optimized saturation scheme was found to be 60 sinc-Gaussian pulses with 40 msec pulse duration, at 50% duty-cycle with continuous-wave pulse equivalent B1 power (B1(CWPE)) of 0.92 mu T. The magnetization transfer (MT) contribution to the fit-model was centered at -1.27 ppm. Intersession coefficients of variation (CVs) of the amide, NOE, and magnetization transfer (MT) and asymmetric magnetization transfer ratio (MTRasym) signals of 25%, 23%, 18%, and 200%, respectively, were observed. Fit-metric and MTRasym CVs agreed between readers to within 4 and 10 percentage points, respectively. Data Conclusion Signal differences of 0.03-0.10 (17-43%) detectable depending upon pool, with MT the most repeatable (signal difference of 17-22% detectable). Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1238-1250.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据