Dropwise condensation on superhydrophobic nanostructure surface, Part I: Long-term operation and nanostructure failure

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2018.09.100

关键词

Dropwise condensation; Superhydrophobic surface; Long-term operation; Droplet removal; Failure

资金

  1. National Natural Science Foundation of China [51436004]
  2. China Postdoctoral Science Foundation [2017M620712]
  3. Fundamental Research Funds for the Central Universities [JB2014005]

向作者/读者索取更多资源

Dropwise condensation heat transfer (DWC) on superhydrophobic nanograsses surface (NGS) was investigated for long-term operation. For DWC of pure water-vapor on fresh NGS, two heat transfer regimes are identified: higher heat transfer coefficients with droplet jumping, and constant heat transfer coefficients with droplet rolling. The one-week operation not only deteriorates heat transfer performance, but also changes jumping or rolling mode to sliding mode. The condensation heat transfer coefficients are apparently decreased from first to third day, but they approach a limit value since the third day. In order to identify if the single-molecule-layer of polymer (SML) modified on nanograsses was destroyed, DWC on a smooth single-molecule-layer of polymer surface (SSML) was tested to display stable heat transfer with drop sliding for one-week operation, concluding no failure of the polymer layer. The collapse and breakage of nanograsses were observed to explain the decayed heat transfer versus time on NGS. Compared with SSML, the NGS has smaller droplet departure size but lower heat transfer coefficients, indicating positive and negative effects after introducing nanostructures. Three nanostructure failure mechanisms are proposed. This work suggests a new research field of the nanoscale fluid-wall interaction. (C) 2018 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据