4.7 Article

Sunlight caused interference in outdoor N, N-diethyl-p-phenylenediamine colorimetric measurement for residual chlorine and the solution for on-site work

期刊

ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY
卷 169, 期 -, 页码 640-644

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.ecoenv.2018.11.055

关键词

Residual chlorine; DPD colorimetric measurement; Water quality; Sun exposure; Ultraviolet; Drinking water

向作者/读者索取更多资源

Chlorination is the most common method to control water qualities, in some case on-site outdoor measurements are required to measure easily-decaying residual chlorine concentration appropriately without delay. In this study sunlight-induced unexpected colour development (UCD) of N, N-diethyl-p-phenylenediamine (DPD) colorimetric measurement was studied under several sun exposure conditions. The colour development level was evaluated with reference to chlorine concentration (mg/L) and relationships between colour development rate (mg/L min) and intensities of solar were investigated. UCD was found to be related to both exposure intensity and time. By means of exposure experiment under specific wavelength of ultraviolet (UV), it was confirmed that both middle and short wavelength of UV radiation being responsible for such an unexpected measurement. Consequently, a simple device was designed using three commercially available anti-UV films, one of which could effectively prevent the UCD from direct sun exposure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据