4.6 Article

Quantitative assessment of placental perfusion by contrast-enhanced ultrasound in macaques and human subjects

期刊

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.ajog.2016.01.001

关键词

contrast-enhanced ultrasound imaging; Japanese macaque; placenta; placental perfusion

资金

  1. National Institutes of Health [R21-HD-076265, R24-DK-090964, P51-OD-011092]
  2. Oregon Health & Science University Knight Cardiovascular Institute Center for Developmental Health
  3. Struble Foundation

向作者/读者索取更多资源

BACKGROUND: The uteroplacental vascular supply is a critical determinant of placental function and fetal growth. Current methods for the in vivo assessment of placental blood flow are limited. OBJECTIVE: We demonstrate the feasibility of the use of contrast-enhanced ultrasound imaging to visualize and quantify perfusion kinetics in the intervillous space of the primate placenta. STUDY DESIGN: Pregnant Japanese macaques were studied at mid second trimester and in the early third trimester. Markers of injury were assessed in placenta samples from animals with or without contrastenhanced ultrasound exposure (n = 6/group). Human subjects were recruited immediately before scheduled first-trimester pregnancy termination. All studies were performed with maternal intravenous infusion of lipid-shelled octofluoropropane microbubbles with image acquisition with a multipulse contrast-specific algorithm with destruction-replenishment analysis of signal intensity for assessment of perfusion. RESULTS: In macaques, the rate of perfusion in the intervillous space was increased with advancing gestation. No evidence of microvascular hemorrhage or acute inflammation was found in placental villous tissue and expression levels of caspase-3, nitrotyrosine and heat shock protein 70 as markers of apoptosis, nitrative, and oxidative stress, respectively, were unchanged by contrast-enhanced ultrasound exposure. In humans, placental perfusion was visualized at 11 weeks gestation, and preliminary data reveal regional differences in intervillous space perfusion within an individual placenta. By electron microscopy, we demonstrate no evidence of ultrastructure damage to the microvilli on the syncytiotrophoblast after first-trimester ultrasound studies. CONCLUSIONS: Use of contrast-enhanced ultrasound did not result in placental structural damage and was able to identify intervillous space perfusion rate differences within a placenta. Contrast-enhanced ultrasound imaging may offer a safe clinical tool for the identification of pregnancies that are at risk for vascular insufficiency; early recognition may facilitate intervention and improved pregnancy outcomes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据