4.5 Article

Dual-Energy CT Material Density Iodine Quantification for Distinguishing Vascular From Nonvascular Renal Lesions: Normalization Reduces Intermanufacturer Threshold Variability

期刊

AMERICAN JOURNAL OF ROENTGENOLOGY
卷 212, 期 2, 页码 366-376

出版社

AMER ROENTGEN RAY SOC
DOI: 10.2214/AJR.18.20115

关键词

dual-energy CT; dual source; iodine; rapid-kilovoltage switching; renal lesions; variability

资金

  1. Siemens Healthcare

向作者/读者索取更多资源

OBJECTIVE. The purpose of this study was to determine whether a single, uniform normalized iodine threshold reduces variability and enables reliable differentiation between vascular and nonvascular renal lesions independent of the dual-energy CT (DECT) platform used. MATERIALS AND METHODS. In this retrospective, HIPAA-compliant, institutional review boardapproved study, 247 patients (156 men, 91 women; mean age +/- SD, 67 +/- 12 years old) with 263 renal lesions (193 nonvascular, 70 vascular) underwent unenhanced single-energy and contrast-enhanced DECT scans. One hundred and six nonvascular and 38 vascular lesions were scanned on two dual-source DECT (dsDECT) scanners, and 87 nonvascular and 32 vascular lesions were scanned on two rapid-kilovoltage-switching single-source DECT (rsDECT) scanners. Optimal absolute and normalized (to aorta) lesion iodine thresholds were determined for each platform type and for the entire cohort combined. RESULTS. Mean optimal absolute discriminant thresholds were 1.3 mg I/mL (95% CI, 1.21.9 mg I/mL), 1.6 mg I/mL (95% CI, 0.91.5 mg I/mL), and 1.5 mg I/mL (95% CI, 1.41.7 mg I/mL) for dsDECT, rsDECT, and combined cohorts, respectively. Optimal normalized discriminant thresholds were 0.3 mg I/mL (95% CI, 0.20.4 mg I/mL) for both the dsDECT and rsDECT cohorts, and 0.3 mg I/mL (0.30.4 mg I/mL) for the combined cohort. The AUC, sensitivity, and specificity for the combined optimal normalized discriminant threshold of 0.3 mg I/mL was 0.96 (95% CI, 0.921.00), 0.93 (0.840.97), and 0.95 (0.910.98), respectively. Normalization resulted in decreased variability and better lesion separation (effect size, 1.77 vs 1.69, p < 0.0001). CONCLUSION. The optimal absolute discriminant threshold for evaluating renal lesions varies depending on the type of DECT platform, though this difference is not statistically significant. Variation can be reduced with a better separation of vascular and nonvascular lesions by normalizing iodine quantification to the aorta.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据