4.0 Article

Coding Human Factors Observations in Surgery

期刊

AMERICAN JOURNAL OF MEDICAL QUALITY
卷 32, 期 5, 页码 556-562

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/1062860616675230

关键词

HFACS; human error; error analysis; latent failures; CVOR

向作者/读者索取更多资源

The reliability of the Human Factors Analysis and Classification System (HFACS) for classifying retrospective observational human factors data in the cardiovascular operating room is examined. Three trained analysts independently used HFACS to categorize observational human factors data collected at a teaching and nonteaching hospital system. Results revealed that the framework was substantially reliable overall (Study I: k = 0.635; Study II: k = 0.642). Reliability increased when only preconditions for unsafe acts were investigated (Study I: k =0.660; Study II: k = 0.726). Preconditions for unsafe acts were the most commonly identified issues, with HFACS categories being similarly populated across both hospitals. HFACS is a reliable tool for systematically categorizing observational data of human factors issues in the operating room. Findings have implications for the development of a HFACS tool for proactively collecting observational human factors data, eliminating the necessity for classification post hoc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据