4.6 Article

The role of accelerometer data calibration within GRACE gravity field recovery: Results from ITSG-Grace2016

期刊

ADVANCES IN SPACE RESEARCH
卷 58, 期 9, 页码 1597-1609

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.asr.2016.08.007

关键词

GRACE; Temporal gravity field; Accelerometer calibration; ITSG-Grace2016

资金

  1. EGSIEM (European Gravity Service for Improved Emergency Management) project in the framework of the European Union's Horizon research and innovative programme [637010]
  2. Austrian Research Promotion Agency (FFG) in the frame of the Austrian Space Applications Programme Phase 11 [847971]

向作者/读者索取更多资源

For more than 14 years, the Gravity Recovery and Climate Experiment (GRACE) mission has provided information about Earth's gravity field with unprecedented accuracy. The twin satellites GRACE-A and GRACE-B are both equipped with a three-axis electrostatic accelerometer, measuring the non-gravitational forces acting on the spacecraft. In order to make use of the uncalibrated Level-1B accelerometer (ACC1B) data during gravity field recovery, bias and scale parameters have to be estimated. The proposed calibration method is a two-step approach and makes use of modeled non-conservative accelerations. The simulated non-conservative accelerations serve as reference for the a priori accelerometer calibration, i.e. for the ACC1B data. During gravity field recovery the calibration parameters are re-estimated. Several calibration parameters for the GRACE accelerometers using different methods have already been published. The aim of our study was primarily to analyze the temperature-dependent behavior of the accelerometer scale factors and biases, and the impact of the parametrization of scale factors and biases on the recovered gravity field solutions; but not to obtain calibrated accelerometer data. Within the ITSG-Grace2016 release, the accelerometer biases are estimated daily using uniform cubic basis splines (UCBS), the scale factors are also estimated daily using a fully-populated scale factor matrix. Therefore, not only the scale factors in along-track, cross track, and radial direction are estimated, but also the non-orthogonality of the accelerometer axes (cross-talk) and the misalignment between the Accelerometer Frame (AF) and Science Reference Frame (SRF) are taken into account. The time evolution of the estimated calibration parameters over the whole GRACE period (2002-04 to 2016-01) shows a clear temperature-dependency for both scale factors and biases. Using this new approach, the estimates of the C20 coefficient significantly improve, with results now comparable to Satellite Laser Ranging (SLR) solutions. Based on the achieved results, we suggest the presence of a clear temperature-dependent behavior and the presence of off-diagonal elements in the accelerometer scale factor matrix. (C) 2016 COSPAR. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据