4.6 Article

Efficacy and Safety of Drug-Eluting Stents Optimized for Biocompatibility vs Bare-Metal Stents With a Single Month of Dual Antiplatelet Therapy A Meta-analysis

期刊

JAMA CARDIOLOGY
卷 3, 期 11, 页码 1050-1059

出版社

AMER MEDICAL ASSOC
DOI: 10.1001/jamacardio.2018.3551

关键词

-

向作者/读者索取更多资源

IMPORTANCE A significant number of patients receive bare-metal stents (BMSs) instead of drug-eluting stents (DESs) to shorten the duration of dual antiplatelet therapy (DAPT). Emerging evidence suggests that new-generation DESs, particularly those optimized for biocompatibility, may be more efficacious and safer than BMSs, even with a single month of DAPT after stent implantation. OBJECTIVE To evaluate the efficacy and safety of DESs compared with BMSs for coronary intervention with a single month of DAPT. DATA SOURCES Human studies found in PubMed, the Cochrane databases through April 2018, and reference lists of selected articles. STUDY SELECTION Randomized clinical trials were included if they enrolled patients undergoing percutaneous coronary intervention and randomly assigned each patient to treatment with either DESs or BMSs. The additional inclusion criterion was use of only 1month of DAPT poststent implantation. DATA EXTRACTION AND SYNTHESIS Two reviewers independently extracted the data. Odds ratios (ORs) were calculated using random-effects models. RESULTS Data from 3 randomized clinical trials involving 3943 patients were included (2457 men [62.3%]; mean [SD] age ranging from 75.7 [9.3] years to 81.4 [43] years per trial subgroup). Coronary intervention with DESs reduced the rates for major adverse cardiac events (OR, 0.68 [95% CI, 0.57-0.82]; P < .001), target lesion revascularization (OR, 0.38 [95% CI, 0.22-0.67]; P = .001), target vessel revascularization (OR, 0.50 [95% CI, 0.38-0.65]; P < .001), and myocardial infarction (OR, 0.51 [95% CI, 0.31-0.83]; P = .01) compared with BMSs at 1 year. The incidence of stent thrombosis was also lower with DESs compared with BMSs (1.8% vs 2.8%), but this difference was not statistically significant in the random-effects model. Additionally, the 2 stent types did not differ in the risks of all-cause mortality, cardiac mortality, and bleeding. CONCLUSIONS AND RELEVANCE In the limited number of randomized clinical trials comparing DESs with BMSs with shortened DAPT durations in patients who have high bleeding risk or are uncertain candidates for prolonged DAPT, coronary intervention with specific DESs optimized for biocompatibility is not only safe but also efficacious, even with only 1 month of DAPT.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据