4.7 Article

Development of a high sensitivity TaqMan-based PCR assay for the specific detection of Mycobacterium tuberculosis complex in both pulmonary and extrapulmonary specimens

期刊

SCIENTIFIC REPORTS
卷 9, 期 -, 页码 -

出版社

NATURE PUBLISHING GROUP
DOI: 10.1038/s41598-018-33804-1

关键词

-

资金

  1. Chang Gung University [SCRPD2G0061]
  2. Chang Gung Memorial Hospital (Linko) [CMRPD2G0062]

向作者/读者索取更多资源

Tuberculosis (TB) causes a heavy health burden worldwide, especially in developing countries. The need for the rapid and accurate diagnosis of TB has not been satisfied, especially for extra-pulmonary specimens or specimens with acid fast stain (AFS)-negative condition. Development and validation of a novel, sensitive and specific assay for diagnosing TB is essential. We developed IS4 primer/probe based on insertion sequence 6110 (IS6110). A qPCR assay was designed for detecting a specific region in IS6110 by BLAST. The IS4 primer/probe concentration, qPCR efficiency and various of PCR additives were evaluated and optimized. Thirty-four species of commonly isolated microorganisms were used for evaluating the analytical specificity. Moreover, 130 clinical specimens were collected for evaluating the performance versus Cobas TaqMan MTB (CTM) assay kit and culture. The amplification efficiencies of IS4 were 99.61% and 102.61% without and with internal control DNA (Bacteriophage Lambda), respectively. Dimethyl sulfoxide outperformed glycerol or BSA for eliciting the most effective amplification and the lowest limit of detection. In evaluating the clinical performance, various specimen types were collected. IS4 demonstrated a high degree of agreement (kappa = 0.71) with CTM. The clinical sensitivity and specificity of IS4 and CTM were 92.11% (35/38), 82.61% (76/92), 84.21% (32/38) and 95.65% (88/92), respectively. The clinical sensitivity and specificity of IS4 were similar for both pulmonary [92.00% (23/25) and 76.92% (30/39), respectively] and extrapulmonary [92.31% (12/13) and 86.79% (46/53), respectively] specimens. Among AFS-negative cases, the clinical sensitivity and specificity remained 90.48% (19/21) and 83.91% (73/87), respectively, with culture as the gold standard. We concluded that IS4, a new primer/probe pair for TaqMan based qPCR assay, was developed, optimized, and validated for the sensitive and specific detection of TB among various specimen types. The performance was not compromised under AFS-negative conditions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据