4.5 Article

The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility

期刊

REVIEW OF SCIENTIFIC INSTRUMENTS
卷 90, 期 1, 页码 -

出版社

AMER INST PHYSICS
DOI: 10.1063/1.5058700

关键词

-

资金

  1. U.S. Department of Energy, National Nuclear Security Administration [DE-AC52-07NA27344]
  2. General Atomics [DE-NA0001808]
  3. U.S. Department of Energy's National Nuclear Security Administration [DE-NA0003525]

向作者/读者索取更多资源

The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broad-band self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 mu m, close to theoretical predictions. Finally, results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration. Published under license by AIP Publishing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据