4.5 Article

Comparison between digital image analysis and visual assessment of immunohistochemical HER2 expression in breast cancer

期刊

PATHOLOGY RESEARCH AND PRACTICE
卷 214, 期 12, 页码 2087-2092

出版社

ELSEVIER GMBH, URBAN & FISCHER VERLAG
DOI: 10.1016/j.prp.2018.10.015

关键词

HER2; Breast cancer; Digital image analysis; Dual in-situ hybridization

资金

  1. Rachadapiseksomphot Endowment Fund of the Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
  2. National Research Council of Thailand Grant under the Research University Network (RUN) Initiative

向作者/读者索取更多资源

Background: Assessment of HER2 status is considered standard of care in the histopathologic workup of breast cancer and conveys prognostic and predictive information used to guide treatment decisions. The assessment is often carried out in a two-step approach where immunohistochemical expression of HER2 protein is first evaluated by conventional microscopy and equivocal cases are further analyzed by in-situ hybridization techniques to assess gene amplification status. In this study we compared conventional manual assessment of immunohistochemical HER2 expression with digital image analysis (DIA) and consensus manual assessment by a panel of three pathologists. Methods: From our archive we retrieved sections of 109 invasive breast carcinomas stained for HER2 with corresponding HER2 score from the original pathology report. The glass slides were assessed by three pathologists to reach a consensus score. Next, the slides were scanned into whole slide images and DIA was performed using Aperio Imagescope. The scoring results were then compared with gene amplification status evaluated by dual in-situ hybridization (DISH). Results: Comparing manual assessment with consensus assessment and DIA, good agreement was obtained with weighted kappa coefficients of 0.79 (manual vs. consensus) and 0.67 (manual vs. DIA). When compared with gene status assessment by DISH, agreement analysis yielded weighted kappa coefficients of 0.52 (manual vs. DISH), 0.58 (consensus vs. DISH) and 0.78 (DIA vs. DISH). There were no false negatives by any of the three methods and false positives ranging from 0.9 to 2.8%. The proportion of equivocal cases by each method was 44% (manual), 33.3% (consensus) and 14.7% (DIA). Application of DIA reduced the number of equivocal cases by 67% without increasing the proportion of false negatives. Conclusion: We conclude that DIA is an accurate method to reduce the number of HER2 equivocal cases without affecting the sensitivity of the HER2 assessment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据