4.6 Article

Studying the Morita-Baylis-Hillman Reaction in Continuous Flow Using Packed Bed Reactors

期刊

ORGANIC PROCESS RESEARCH & DEVELOPMENT
卷 22, 期 11, 页码 1524-1533

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.oprd.8b00298

关键词

Morita-Baylis-Hillman; continuous flow; packed bed reactor; DMAP catalysis; scale-out

资金

  1. Independent Research Fund Denmark-Technology and Production [414800031]
  2. Danish National Research Foundation [DNRF118]
  3. Carlsberg Foundation [CF17-0517]
  4. Aarhus University

向作者/读者索取更多资源

Conditions for the Morita-Baylis-Hillman reaction were developed under continuous flow using a packed bed reactor carrying 4-(dimethylamino)pyridine immobilized on silica. High reaction rates were obtained, as the packed bed reactor mimics super-stoichiometric catalyst loadings for the passing reaction mixture. Catalyst deactivation was circumvented by avoiding acrylate esters as the reaction partners. The developed flow protocol provided all desired Morita-Baylis-Hillman products in yields attaining 95% with typical retention times between just 30 and 60 min. Precise control of the retention time proved imperative for one example, in which optimal yield was attained in just 10 min, while outpacing sideproduct formation. Finally, a scale-out study was performed proving high stability of the packed bed reactor setup and catalyst for more than 20 h of operation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据