4.6 Article

Thermal behavior in the cracking reaction zone of scramjet cooling channels at different channel aspect ratios

期刊

ACTA ASTRONAUTICA
卷 127, 期 -, 页码 41-56

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.actaastro.2016.05.015

关键词

Scramjet engine; Regenerative cooling; Thermal behavior; 3-D; Channel aspect ratio; Cracking reaction

资金

  1. China Scholarship Council [51476044, 51276047]
  2. Shenzhen Technology Project [JCYJ20150529115038093]
  3. Innovative Research Groups of National Natural Science Foundation of China [51421063]

向作者/读者索取更多资源

To study the thermal behavior in the cracking reaction zone of regeneratively cooled scramjet cooling channels at different aspect ratios, 3-D model of fuel flow in terms of the fuel's real properties and cracking reaction is built and validated through experiments. The whole cooling channel is divided into non-cracking and cracking reaction zones. Only the cracking reaction zone is studied in this article. The simulation results indicate that the fuel conversion presents a similar distribution with temperature because the fuel conversion in scramjet cooling channels is co-decided by the temperature and velocity but the temperature plays the dominate role. For the cases given in this paper, increasing the channel aspect ratio Will increase the pressure drop and it is not beneficial for reducing the wall temperature because of the much severer thermal stratification, larger conversion non-uniformity, the corresponding M-shape velocity profile which will cause local heat transfer deterioration and the decreased chemical heat absorption. And the decreased chemical heat absorption caused by stronger temperature and conversion non-uniformities is bad for the utilization of chemical heat sink, chemical recuperation process and the ignition performance. (C) 2016 IAA. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据