Comparison of gamma ray localization using system matrixes obtained by either MCNP simulations or ray-driven calculations for a coded-aperture imaging system

出版社

ELSEVIER
DOI: 10.1016/j.nima.2018.10.031

关键词

Coded-aperture; MCNP simulation; Ray-driven; System matrix; Image reconstruction; Gamma ray localization

资金

  1. National Research Foundation of Republic of Korea [NRF-2010 0020077, NRF-2018M3A7B4070992]
  2. National Research Foundation of Korea (NRF) - Korea government
  3. National Research Foundation of Korea [2018M3A7B4070992] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

A coded-aperture system based on a large-area silicon photo-multiplier (SiPM) coupled with inorganic scintillator was developed for the gamma ray localization in the field of nuclear safety and security. Monte Carlo simulations of the performance were conducted to verify its performance. For the coded-aperture imaging (CAI) system, the mask was designed with an 11-rank modified uniformly redundant array (MURA), and the SiPM readout consisted of 12 x 12 pixels. A two-centimeter-thick tungsten mask was used to encode the gamma ray field. The 144 pixels are read-out with a resistor-based charge-division circuit that reduces the readout outputs from 144 to four signals per module, from which the deposited energy and interaction position can be extracted. For image localization, maximum-likelihood expectation maximization (MLEM) and compress-sensing (CS) methods are used with either: (1) a system matrix generated both the Monte-Carlo N-Particle (MCNP) code, or (2) a mathematical system-matrix model utilizing a ray-driven method. In this paper, reconstructed images of gamma ray sources with various positions and activities were simulated and measured with the simulation tools and the physical system in order to compare and evaluate the relative strengths of the two different system matrix formulations. Both system matrixes generated by MCNP and ray-driven methods are effective in localizing isolated point sources; however, there are critical differences when several gamma sources with different strengths are in the field of view. Although the MCNP-based system matrix requires more processing time to generate, its more accurate incorporation of the competing gamma-ray interaction processes results in effective localization of multiple point sources. In contrast, the rapidly produced ray-driven reconstruction matrix demonstrates reduced accuracy in localizing extending distributions due to its simplified treatment of the particle transport, the magnitude of which is quantified in the paper.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据