4.4 Article

A new highly sensitive enzyme-linked immunosorbent assay for the detection of Plasmodium falciparum histidine-rich protein 2 in whole blood

期刊

MALARIA JOURNAL
卷 17, 期 -, 页码 -

出版社

BMC
DOI: 10.1186/s12936-018-2545-5

关键词

Plasmodium falciparum; Malaria; Enzyme-linked immunosorbent assay; Histidine-rich protein 2; Elimination

资金

  1. Bill & Melinda Gates Foundation [OPP1135840]
  2. Bill and Melinda Gates Foundation [OPP1135840] Funding Source: Bill and Melinda Gates Foundation

向作者/读者索取更多资源

BackgroundThe detection of submicroscopic infections in low prevalence settings has become an increasingly important challenge for malaria elimination strategies. The current field rapid diagnostic tests (RDTs) for Plasmodium falciparum malaria are inadequate to detect low-density infections. Therefore, there is a need to develop more sensitive field diagnostic tools. In parallel, a highly sensitive laboratory reference assay will be essential to evaluate new diagnostic tools. Recently, the highly sensitive Alere Malaria Ag P.f ELISA (HS ELISA) was developed to detect P. falciparum histidine-rich protein 2 (HRP2) in clinical whole blood specimens. In this study, the analytical and clinical performance of the HS ELISA was determined using recombinant P. falciparum HRP2, P. falciparum native culture parasites, and archived highly pedigreed clinical whole blood specimens from Karen village, Myanmar and Nagongera, Uganda.ResultsThe HS ELISA has an analytical sensitivity of less than 25pg/mL and shows strong specificity for P. falciparum HRP2 when tested against P. falciparum native culture strains with pfhrp2 and pfhrp3 gene deletions. Additionally, the Z-factor statistic of 0.862 indicates the HS ELISA as an excellent, reproducible assay, and the coefficients of variation for inter- and intra-plate testing, 11.76% and 2.51%, were acceptable. Against clinical whole blood specimens with concordant microscopic and PCR results, the HS ELISA showed 100% (95% CI 96.4-100) diagnostic sensitivity and 97.9% (95% CI 94.8-99.4) diagnostic specificity. For P. falciparum positive specimens with HRP2 concentrations below 400pg/mL, the sensitivity and specificity were 100% (95% CI 88.4-100) and 88.9% (95% CI 70.8-97.6), respectively. The overall sensitivity and specificity for all 352 samples were 100% (CI 95% 96-100%) and 97.3% (CI 95% 94-99%).ConclusionsThe HS ELISA is a robust and reproducible assay. The findings suggest that the HS ELISA may be a useful tool as an affordable reference assay for new ultra-sensitive HRP2-based RDTs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据