4.4 Article

Comparison of an Er: YAG laser osteotome versus a conventional drill for the use in osteo- odonto-keratoprosthesis (OOKP)

期刊

LASERS IN SURGERY AND MEDICINE
卷 51, 期 6, 页码 531-537

出版社

WILEY
DOI: 10.1002/lsm.23053

关键词

osteo-odonto-keratoprosthesis; bone resorption; laser osteotomy; Er; YAG laser; bur; teeth; corneal blindness; scanning electron microscope

资金

  1. Center of Competence for Military and Disaster Medicine, Switzerland

向作者/读者索取更多资源

Objectives The osteo-odonto-kerato-prosthesis (OOKP) procedure is a complex, multi-stage, multidisciplinary surgical intervention for the treatment of severe corneal blindness. One step of the OOKP consists of creating a precise hole into a tooth in which an optic cylinder is subsequently inserted; its shape must ensure a perfect watertight fit. The Er: YAG laser (L) used in this study is part of CARLO (R), the first laser osteotome that enables surgical planning based on computed tomography data, robot guidance, and a precise execution of laser cuts in teeth and bone tissue, using laser photoablation rather than conventional mechanical methods. The purpose of this study was to assess whether the Er: YAG laser is non-inferior compared to a conventional drill. Methods Thirty-two bovine incisors were grounded to a thickness of 1.5 mm. In 16 teeth, a 3.5 mm hole was drilled progressively into each tooth, using dental burs (B) of increasing diameter that were attached to a fixed drill machine. In the other 16 teeth, a hole was created using an Er: YAG laser at a wavelength of 2.94 mu m (Part of CARLO (R)). In seven teeth of each group, the cylinder was inserted and fixated with polymethylmethacrylate (PMMA) bone cement. In the remaining seven teeth of each group, the cylinder was inserted without fixation material (press-fit). After bonding and drying, all specimens were stored in water until force measurements were recorded using a uniaxial traction machine. The force required to move the optical cylinder out of the hole in the tooth was measured using an Instron 3344 testing system. Scanning electron microscope (SEM) and light microscope (LM) visualization of the holes created with the laser and the drill were performed in two teeth (SEM)/four teeth (LM) per method. Results Significant differences (P < 0.001) were found for the following parameters: B PMMA versus B press-fit; B PMMA versus L press-fit; L PMMA versus B press-fit; L PMMA-L press-fit. This shows that PMMA bone cement fixation is superior to press-fit. No significant differences were found between B PMMA-L PMMA (P = 0.93) and B press-fit-L press-fit (P = 0.83). The SEM pictures showed a smoother surface using L. Conclusions The laser cut holes were as strong as bur-drilled holes, although SEM pictures showed a smoother surface of the laser cut holes. Hence, laser osteotomes open the possibility to custom fit the hole exactly to the width of the cylinder, which represents a potential advantage of the laser over the conventional bur. Lasers Surg. Med. 51:531-537, 2019. (c) 2019 Wiley Periodicals, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据