4.8 Article

An Integrated Liquid Cooling System Based on Galinstan Liquid Metal Droplets

期刊

ACS APPLIED MATERIALS & INTERFACES
卷 8, 期 3, 页码 2173-2180

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsami.5b10769

关键词

liquid metal; Galinstan; convective cooling; integrated cooling system; electrowetting; Marangoni effect; heat sink

向作者/读者索取更多资源

The continued miniaturization of electronic components demands integrated liquid cooling systems with minimized external connections and fabrication costs that can be implanted very close to localized hot spots. This might be challenging for existing liquid cooling systems because most of them rely on external pumps, connecting tubes, and microfabricated heat sinks. Here, we demonstrate an integrated liquid cooling system by utilizing a small droplet of liquid metal Galinstan, which is placed over the hot spot. Energizing the liquid metal droplet with a square wave signal creates a surface tension gradient across the droplet, which induces Marangoni flow over the surface of droplet. This produces a high flow rate of coolant medium through the cooling channel, enabling a soft pump. At the same time, the high thermal conductivity of liquid metal extends the heat transfer surface and facilitates the dissipation of heat, enabling a soft heat sink. This facilitates the rapid cooling of localized hot spots, as demonstrated in our experiments. Our technology facilitates customized liquid cooling systems with simple fabrication and assembling processes, with no moving parts that can achieve high flow rates with low power consumption.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据