4.4 Article

Improving the Detection Accuracy and Time for Campylobacter jejuni and Campylobacter coli in Naturally Infected Live and Slaughtered Chicken Broilers Using a Real-Time Fluorescent Loop-Mediated Isothermal Amplification Approach

期刊

JOURNAL OF FOOD PROTECTION
卷 82, 期 2, 页码 189-193

出版社

INT ASSOC FOOD PROTECTION
DOI: 10.4315/0362-028X.JFP-18-179

关键词

Broiler chicken; Campylobacter coli; Campylobacter jejuni; Faster detection; Field applicable; Fluorescent loop-mediated isothermal amplification

资金

  1. Ito Foundation
  2. AMED [JP18jk021007]
  3. JSPS KAKENHI [JP18K05535]

向作者/读者索取更多资源

Rapid and accurate identification of Campylobacter-positive broiler flocks and carcasses expedites separation and control interventions before release into the food supply chain and directly facilitates a reduction in the prevalence of human campylobacteriosis. In this study, the diagnostic performance of fluorescent loop-mediated isothermal amplification (LAMP) assays for the direct detection of Campylobacter jejuni and Campylobacter coli in broiler cloacal and cecal samples were evaluated and compared with that of turbidimetric LAMP approaches investigated previously. The duplex fluorescent LAMP assay had significantly higher (P < 0.05) diagnostic sensitivity (93.1%, 54 of 58 samples) than did the turbidimetric LAMP assay (82.8%, 48 of 58 samples) for detecting C. jejuni and C. coli in broiler cloacal samples, whereas the singleplex fluorescent LAMP assay had equivalent diagnostic sensitivity. For cecal samples, the diagnostic sensitivity of the fluorescent LAMP assay (100%, 38 of 38 samples) was the same as that of the turbidimetric LAMP. Fluorescent LAMP significantly reduced (P < 0.05) the maximum detection time for Campylobacter-positive cloacal and cecal samples to 28 and 11 min, respectively, and reduced the influence of amplification inhibitors responsible for most false-negative results obtained for cloacal samples with the turbidimetric LAMP assay. The diagnostic accuracy of the fluorescent LAMP assay for the direct detection of C. jejuni and C. coli in cloacal and cecal samples was 97.7 and 100%, respectively. These findings indicate that fluorescent LAMP assays are robust, highly accurate, and field-applicable methods for the identification of C. jejuni and C. coli, which will allow more accurate monitoring of food safety at various stages of the food supply chain at farms and slaughter facilities.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据