4.5 Article

Experimental investigation of ventilated partial cavitation

期刊

INTERNATIONAL JOURNAL OF MULTIPHASE FLOW
卷 113, 期 -, 页码 153-164

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijmultiphaseflow.2019.01.007

关键词

Ventilated partial cavitation; Backward-facing cavitator; Cavity regime; Cavity length; Gas leakage

资金

  1. China Scholarship Council [CSC 201706320226]
  2. Office of Naval Research [N000141612755]

向作者/读者索取更多资源

This study presents the experimental investigation on the cavity regime and the corresponding geometric characteristic of ventilated partial cavitation (VPC). Experiments are conducted in the high-speed water tunnel at Saint Anthony Falls Laboratory. A backward-facing cavitator mounted on the ceiling of test section is used to generate the VPC. The flow filed and the dynamic motion of VPC are captured by the imaging system under varying water speeds and ventilation rates. Four distinct cavity regimes are classified, referred to as foamy cavity (FC), transition cavity (TC), open cavity (OC) and two-branch cavity (TBC). The distribution of these cavity regimes over Froude number (Fr) and ventilation coefficient (C-Qs) is summarized in a regime map with FC and TBC occupying the majority portion of the map. More importantly, the C-Qs - Fr curves demarcating neighboring cavity regimes are revealed satisfying a clear linear relation for FC-TC and a quadratic relation for TC-OC and OC-TBC when Fr is subtracted with a constant corresponding to the inception condition of the cavity regime. Such trends are attributed to the two gas entrainment mechanisms present in VPC, referred to as recirculating vortex entrainment and cavity closure entrainment. Moreover, the geometric characteristic of VPC characterized by the cavity length is examined. With increasing ventilation at fixed Fr, the cavity length grows linearly in OC regime and remains unchanged in TBC regime. The maximum cavity length of OC is found to be within around 7 times of cavitator height. With increasing Fr at fixed ventilation, the cavity length first grows proportional to Fr-2 in TBC regime but drops sharply with a small increase of Fr when the cavity transitions from TBC to OC. At fixed Fr, the cavity underpressure rises to maximum (minimum sigma(c)) and stays unchanged in TBC upon increasing ventilation. As a result, in TBC, the cavity length is shown to satisfy a power law relation with respect to Fr or sigma(c), while in OC, the cavity length is influenced by the interplay among C-Qs, sigma(c) and Fr with no clear trend observed. (C) 2019 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据