4.4 Article

Intercondylar eminence fracture treated by resorbable magnesium screws osteosynthesis: A case series

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.injury.2018.09.055

关键词

Knee; Tibia; Fracture; Intercondylar; Eminence; Avulsion; Magnesium; Resorbable; Screws; Osteosynthesis

向作者/读者索取更多资源

Introduction: Tibial spine avulsion fractures are mostly a paediatric injury which appropriate treatment is currently debated in literature. The choice between conservative and surgical treatment is based on the radiographic classification of Meyers-McKeever. The most diffused surgical techniques involve either internal fixation devices (screws) or bone tunnels fixation with resorbable sutures. Today, a third option is represented by resorbable magnesium screws which could combine the best features of the two classical systems. Objective of this study is to investigate the efficacy of these new devices in the surgical treatment of tibial spine avulsions. Materials and methods: Since 2014 we have seen seven patients with tibial eminence fracture. Patients underwent clinical and radiological examination (MRI, CT scan) before surgery. Only 3 patients that presented with a grade III or IV lesion were treated surgically with internal fixation with magnesium resorbable screws. In post-operative follow-up, functional recovery was evaluated at 1, 2, 4, 6 and 12 months, clinically and by X-ray. Lysholm and IKDC scores were submitted at 1, 2, 6 and 12 months. MRI was repeated at 6 and 12 months. Results: All three surgical patients showed progressive clinical and functional improvement during the follow-up period. The first case showed a quicker overall recovery rate, which might be due to the lower grade of the lesion. Radiographs and MRI evaluation showed regular healing of the injury. The devices appeared completely resorbed at the 6 months follow-up and replaced by newly formed bone at the 12 months follow-up. Conclusions: The treatment of tibial spine avulsion fractures with arthroscopic reduction and internal fixation (ARIF) technique by magnesium resorbable screws seems to result in an excellent functional recovery without complications related to fixation devices, which were completely resorbed after 6 months and replaced by newly formed bone after 12 months. This new method could be considered as an alternative option to classic techniques by non resorbable fixation devices or bone tunnel fixation. Further studies are needed in order to evaluate the efficacy of these new devices in a wider group of patients. (C) 2018 The Authors. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据