期刊
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING
卷 27, 期 1, 页码 66-75出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNSRE.2018.2885283
关键词
Motor unit; firing pattern; high-density electromyogram; dynamic contraction; decomposition; motor unit action potential
资金
- Slovenian Research Agency [J2-7357, P2-0041]
We describe the method for identification of motor unit (MU) firings from high-density surface electromyograms (hdEMG), recorded during repeated dynamic muscle contractions. A new convolutive data model for dynamic hdEMG is presented, along with the pulse-to noise ratio (PNR) metric for assessment of MU identification accuracy and analysis of the impact of MU action potential (MUAP) changes in dynamic muscle contractions on MU identification. We tested the presented methodology on signals from biceps brachii, vastus lateralis, and rectus famoris muscles, all during different speeds of dynamic contractions. In synthetic signals with excitation levels of 10%, 30% and 50%, and MUAPs experimentally recorded from biceps brachii muscle, the presented method identified 15 +/- 1, 18 +/- 1, and 20 +/- 1 MUs per contraction, respectively, all with average sensitivity and precision >90% and PNR >30 dB. In experimental signals acquired during low force contractions of vastus lateralis and rectus femoris muscle, the method identified 9.4 +/- 1.9 and 7.8 +/- 1.4 MUs with PNR values of 35.4 +/- 3.6 and 34.1 +/- 2.7 dB. In comparison with the previously introduced Convolution Kernel Compensation method, the capability of the new method to follow dynamic MUAP changes is confirmed, also in relatively fast muscle contractions.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。