Risk of bacterial exposure to the endoscopist's face during endoscopy

期刊

GASTROINTESTINAL ENDOSCOPY
卷 89, 期 4, 页码 818-824

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.gie.2018.10.034

关键词

-

向作者/读者索取更多资源

Background and Aims: Nonuniversal use of facial protection during endoscopy may place endoscopists at risk of exposure to blood and body fluids; however, the frequency of exposure is unknown. Methods: A prospective 6-month study of 4 gastroenterologists using a face shield during endoscopy was undertaken. The face shield was swabbed in a standardized fashion before and at the end of the session. Controls included pre- and post-swabs of face shields placed on the (1) endoscopy suite wall, (2) remote patient intake bay wall, and (3) after deliberate contamination with a colonoscope immediately after colonoscopy. The swabs were cultured for 48 hours, and growth was reported as no growth or by number of colony-forming units (CFUs). The groups were compared for +CFU rate and CFU number. Results: A total of 1100 procedures were performed in 239 endoscopy sessions. The +CFU rate in the preendoscopy groups (2%-4.8%, not significant) was significantly lower than the postendoscopist face shield (45.8%, P<.001) and endoscopy suite wall groups (21.4%, P<.001), respectively. Using a cut-off of >15 CFUs as an indicator of definite exposure, the occurrence rate was 5.6 per 100 half days of endoscopy to the endoscopist's face and 3.4 per 100 half days of endoscopy 6 feet away. Conclusions: This is the first study to quantify the rate of unrecognized exposure to the endoscopist's face to potentially infectious biologic samples during endoscopy (5.6/100 days of endoscopy). This exposure may result in transmission of infectious diseases. As such, we recommend the use of universal facial protection during GI endoscopy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据