4.8 Article

Equivalent Accuracy of 2 Quantitative Fecal Immunochemical Tests in Detecting Advanced Neoplasia in an Organized Colorectal Cancer Screening Program

期刊

GASTROENTEROLOGY
卷 155, 期 5, 页码 1392-+

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1053/j.gastro.2018.07.021

关键词

iFOBT; Occult Blood Test; Diagnostic Yield; Accuracy

资金

  1. Netherlands Organization for Health Research and Development of the Dutch Ministry of Health (ZonMw) [200350001]

向作者/读者索取更多资源

BACKGROUND & AIMS: Although different brands of fecal immunochemical tests (FITs) are used for colorectal cancer (CRC) screening, few studies have compared their accuracy in detecting advanced neoplasia. METHODS: We performed a large prospective cohort study within the Dutch national CRC screening program to evaluate 2 quantitative FITs: FOB-Gold (Sentinel, Milan, Italy) and OC-Sensor (Eiken Chemical, Tokyo Japan), from May 2016 through March 2017. We randomly selected 42,179 screening-naive individuals (55-75 years old), who were asked to perform both FITs themselves using the same bowel movement. Participants with positive results from 1 or both FITs (similar to 15 mg hemoglobin/gram feces) were invited for colonoscopy examination (reference standard). Equivalence in detection of advanced neoplasia was evaluated with a predefined margin of 0.15%. RESULTS: Of 42,179 invitees, 22,064 (52%) participated and FITs were completed for 21,078 participants. Of 2112 participants (9.6%) with 1 or 2 positive results from FITs, 1778 (84%) underwent a colonoscopy. Of all invitees, the FOB-Gold test detected advanced neoplasia (confirmed by colonoscopy) in 610 participants (1.45%) and the OC-Sensor detected advanced neoplasia (confirmed by colonoscopy) in 606 participants (1.44%)-an absolute difference of 0.01% (95% confidence interval [CI], -0.06% to 0.08%). Of the 21,078 participants who completed both FITs, 1582 (7.5%) had a positive result from the FOB-Gold test and 1627 (7.7%) a positive result from the OC-Sensor test (P=.140). The relative true-positive rate of FOB-Gold vs OC-Sensor in detecting advanced neoplasia was 0.97 (95% CI, 0.92-1.01) and 0.95 (95% CI, 0.87-1.03) for CRC. The relative false-positive rate of the FOB-Gold test vs the OC-Sensor test in detecting advanced neoplasia was 0.99 (95% CI, 0.93-1.05). CONCLUSIONS: In a large prospective study of individuals invited for CRC screening in The Netherlands, we found equivalent accuracy of the FOB-Gold FIT vs the OC-Sensor FIT in detecting advanced neoplasia. These results are relevant for selecting FITs for CRC screening programs worldwide. Dutch National Trial Registry: NTR5874.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据