4.7 Article

Spray morphology transformation of propane, n-hexane and iso-octane under flash-boiling conditions

期刊

FUEL
卷 236, 期 -, 页码 677-685

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.fuel.2018.08.160

关键词

Spray; Flash boiling; Gasoline direct injection; Collapse; Nucleation

资金

  1. National Key R&D Program of China [2018YFB0106000]

向作者/读者索取更多资源

Spray collapse has been widely observed under both flash-boiling and non-flash-boiling conditions when multihole gasoline direct injection (GDI) injectors with compact nozzle configurations were used. The main objective of this study is to further understand the collapse mechanisms by using liquids with appreciably different properties (propane, n-hexane and iso-octane). The tests were carried out in a constant volume vessel with ambient pressures ranging from 0.6 bar to 11.0 bar and fuel temperatures from 30 degrees C to 110 degrees C. Flashing propane sprays presented a non-collapse feature under elevated-ambient-pressures but flash-boiling conditions. By close-up examination of flashing propane sprays over a wide range of liquid temperatures and ambient pressures, it was found that there should be an ambient pressure threshold between 1.0 and 3.0 bar between the collapsed and the non-collapse sprays for propane. The spray collapse occurred as the ambient pressure is below the threshold. The non-collapse feature for flashing propane sprays under the ambient pressures beyond the threshold was attributed to the prohibition of nucleation and bubble growth under elevated ambient pressures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据