4.7 Article

Intrauterine fetal MR versus postmortem MR imaging after therapeutic termination of pregnancy: evaluation of the concordance in the detection of brain abnormalities at early gestational stage

期刊

EUROPEAN RADIOLOGY
卷 29, 期 6, 页码 2740-2750

出版社

SPRINGER
DOI: 10.1007/s00330-018-5878-0

关键词

Fetuses; Magnetic resonance imaging; Brain; Termination of pregnancy; Counseling

向作者/读者索取更多资源

Background and purposeFetal postmortem MR Imaging (pmMRI) has been recently used as an adjuvant tool to conventional brain autopsy after termination of pregnancy (TOP). Our purpose was to compare the diagnostic performance of intrauterine MRI (iuMRI) and pmMRI in the detection of brain anomalies in fetuses at early gestational age (GA).Material and methodsWe retrospectively collected 53 fetuses who had undergone iuMRI and pmMRI for suspected brain anomalies. Two pediatric neuroradiologists reviewed iuMRI and pmMRI examinations separately and then together. We used Cohen's K to assess the agreement between pmMRI and iuMRI. Using the combined evaluation iuMRI+pMRI as the reference standard, we calculated the correctness ratio. We used Somers' D to assess the cograduation between postmortem image quality and time elapsed after fetus expulsion.ResultsOur data showed high agreement between iuMRI and pmMRI considering all the categories together, for both observers (K1 0.84; K2 0.86). The correctness ratio of iuMRI and pmMRI was 79% and 45% respectively. The major disagreements between iuMRI and pmMRI were related to postmortem changes as the collapse of liquoral structures and distorting phenomena. We also found a significant cograduation between the time elapsed from expulsion and pmMRI contrast resolution and distortive phenomena (both p<0.001).ConclusionsOur study demonstrates an overall high concordance between iuMRI and pmMRI in detecting fetal brain abnormalities at early GA. Nevertheless, for the correct interpretation of pmMRI, the revision of fetal examination seems to be crucial, in particular when time elapsed from expulsion is longer than 24h.Key Points center dot IuMRI and pmMRI showed overall high concordance in detecting fetal brain abnormalities at early GA.center dot PmMRI corroborated the antemortem diagnosis and it could be a valid alternative to conventional brain autopsy, only when the latter cannot be performed.center dot Some caution should be taken in interpreting pmMR images when performed after 24h from fetal death.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据