4.6 Article

Thoracic endografting increases cardiac afterload and leads to left ventricular hypertrophy in dogs

期刊

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
卷 55, 期 4, 页码 618-625

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/ejcts/ezy402

关键词

Thoracic endovascular aortic repair; Aortic input impedance; Cardiac remodelling

资金

  1. Ministry of Education, Culture, Sports, Science and Technology of Japan (MEXT) [15K10245]
  2. Grants-in-Aid for Scientific Research [15K10245] Funding Source: KAKEN

向作者/读者索取更多资源

OBJECTIVES Aortic endografting can cause aortic stiffening. We aimed to determine the chronic effect of thoracic endografting on cardiac afterload, function and remodelling. METHODS Eleven dogs were included, and all except 1 was successfully assessed [endograft, n=5; sham operation (control), n=5]. We deployed a stent graft in the descending aorta. The ascending aortic pressure and flow were measured, and aortic input impedance was obtained by frequency analysis to determine characteristic impedance and arterial compliance. Left ventricular pressure-volume relations were measured with an admittance catheter. Measurements were performed before, 10min after and 3months after endografting. Following euthanasia, we weighed the left ventricle of each dog and measured the cardiomyocyte cell size. RESULTS Arterial compliance decreased from 0.470.07 to 0.36 +/- 0.06 and to 0.31 +/- 0.05ml/mmHg (both P<0.01 versus baseline), and characteristic impedance increased from 0.11 +/- 0.04 to 0.19 +/- 0.05 and to 0.21 +/- 0.04mmHg/ml/s (both P<0.01 versus baseline) 10min and 3months after endografting, respectively. Pressure-volume relation analysis showed that arterial elastance increased from 5.3 +/- 1.0 to 6.7 +/- 1.6 (at 10min) and to 6.8 +/- 1.0mmHg/ml (at 3months) (both P<0.05 versus baseline), but end-systolic elastance and ventriculo-arterial coupling remained unchanged. Left ventricular weight to body weight ratio and left ventricular cardiomyocyte cell width in the endograft group were larger compared with the control's results (5.06 +/- 0.27g/kg vs 4.20 +/- 0.49g/kg, P=0.009, 15.1 +/- 1.7 mu m vs 13.9 +/- 1.5 mu m, P=0.02, respectively). CONCLUSIONS The mid-term effect of the descending aortic endografting on left ventricular contractility and efficiency in canine normal hearts was minimal. However, endografting resulted in increased cardiac afterload and left ventricular hypertrophy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据