4.6 Article

Volatile Organic Compounds in Patients With Acute Kidney Injury and Changes During Dialysis*

期刊

CRITICAL CARE MEDICINE
卷 47, 期 2, 页码 239-246

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0000000000003523

关键词

breath analysis; continuous venovenous hemodialysis; critical care; mechanical ventilation; renal replacement therapy; volatile organic compound

向作者/读者索取更多资源

Objectives: To characterize volatile organic compounds in breath exhaled by ventilated care patients with acute kidney injury and changes over time during dialysis. Design: Prospective observational feasibility study. Setting: Critically ill patients on an ICU in a University Hospital, Germany. Patients: Twenty sedated, intubated, and mechanically ventilated patients with acute kidney injury and indication for dialysis. Interventions: Patients exhalome was evaluated from at least 30 minutes before to 7 hours after beginning of continuous venovenous hemodialysis. Measurements and Main Results: Expired air samples were aspirated from the breathing circuit at 20-minute intervals and analyzed using multicapillary column ion-mobility spectrometry. Volatile organic compound intensities were compared with a ventilated control group with normal renal function. A total of 60 different signals were detected by multicapillary column ion-mobility spectrometry, of which 44 could be identified. Thirty-four volatiles decreased during hemodialysis, whereas 26 remained unaffected. Forty-five signals showed significant higher intensities in patients with acute kidney injury compared with control patients with normal renal function. Among these, 30 decreased significantly during hemodialysis. Volatile cyclohexanol (23 mV; 25-75th, 19-38), 3-hydroxy-2-butanone (16 mV, 9-26), 3-methylbutanal (20 mV; 14-26), and dimer of isoprene (26 mV; 18-32) showed significant higher intensities in acute kidney impairment compared with control group (12 mV; 10-16 and 8 mV; 7-14 and not detectable and 4 mV; 0-6; p < 0.05) and a significant decline after 7 hours of continuous venovenous hemodialysis (16 mV; 13-21 and 7 mV; 6-13 and 9 mV; 8-13 and 14 mV; 10-19). Conclusions: Exhaled concentrations of 45 volatile organic compounds were greater in critically ill patients with acute kidney injury than in patients with normal renal function. Concentrations of two-thirds progressively decreased during dialysis. Exhalome analysis may help quantify the severity of acute kidney injury and to gauge the efficacy of dialysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据