期刊
CIRCULATION
卷 139, 期 1, 页码 67-77出版社
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.118.037707
关键词
clinical trial; coronary artery disease; drug-eluting stents; drug therapy; thrombosis
资金
- University Medical Center Utrecht
BACKGROUND: Polymer-free amphilimus-eluting stents (PF-AES) represent a novel elution technology in the current era of drug-eluting stents. The clinical safety and efficacy of PF-AES as compared with latestgeneration permanent-polymer zotarolimus-eluting stents (PP-ZES) have not yet been investigated in a large randomized trial. METHODS: In this physician-initiated, prospective, multicenter, randomized, noninferiority trial, an all-comers population requiring percutaneous coronary intervention was enrolled across 3 European sites. Randomization (1: 1 ratio) to PP-ZES or PF-AES was performed after stratification for troponin status and diabetes mellitus. In both treatment arms, troponin-positive patients were planned for 12-month dual antiplatelet therapy, whereas troponin-negative patients were planned for 1-month dual antiplatelet therapy. Outcome assessors were blinded to the allocated treatment. The device-oriented primary end point of target-lesion failure was defined as cardiac death, target-vessel myocardial infarction, or target-lesion revascularization at 12-months as analyzed by modified intention-to-treat (80% power, and a 3.5% noninferiority margin). RESULTS: In total, 1502 patients were randomized and 1491 treated with the assigned stent and available for follow-up. The primary end point occurred in 42 (5.6%) of the 744 patients receiving PP-ZES versus 46 (6.2%) of the 747 patients receiving PF-AES. PF-AES were clinically noninferior to PP-ZES (risk difference, 0.5%; upper limit 1-sided 95% confidence interval, 2.6%; P-noninferiority = 0.0086). Cardiac death occurred in 10 (1.3%) versus 10 patients (1.3%; P value for difference, 1.00), targetvessel myocardial infarction occurred in 18 (2.4%) versus 17 patients (2.3%; P value for difference, 0.87), and target-lesion revascularization occurred in 22 (2.9%) versus 20 patients (2.6%; P value for difference, 0.75) for PF-AES as compared with PP-ZES. Overall, definite or probable stent thrombosis occurred in 1.0%. CONCLUSIONS: PF-AES were noninferior to PP-ZES regarding targetlesion failure at 12 months. Findings regarding the secondary end point and prespecified subgroups were generally consistent with that of the primary end point.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据