4.5 Article Proceedings Paper

Evaluation-independent system for DNA section amplification

期刊

BIOMEDICAL ENGINEERING ONLINE
卷 17, 期 -, 页码 -

出版社

BMC
DOI: 10.1186/s12938-018-0580-7

关键词

Gel documentation system; Gel image analysis; DNA detection; Fluorescence; Optics; NTC thermistor; Thermocouple; Side illumination

资金

  1. Ministry of Trade, Industry & Energy (MOTIE, Korea) under Industrial Technology Innovation Program [10053617]
  2. National Research Foundation of Korea (NRF) - Ministry of Science, ICT and future Planning [NRF-2017R1A2B1010125]
  3. Korea Evaluation Institute of Industrial Technology (KEIT) [10053617] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

BackgroundIn general, the image analysis of nucleic acid for detecting DNA is dependent on the gel documentation system. These experiments may deal with harmful staining agents and are time consuming. To address these issues, real-time polymerase chain reaction (PCR) devices have been developed. The advantages of real-time PCR are its capabilities for real-time diagnosis, improved sensitivity, and digitization of measurement results. However, real-time PCR equipment is still too bulky and expensive for use in small hospitals and laboratories.MethodsThis paper describes an evaluation-independent real-time PCR system that differs from conventional systems in that it uses a side-illumination optical detection system and a temperature adjustment coefficient for DNA detection. The overall configuration of the evaluation-independent system includes the PCR chip and system hardware and software. The use of the side-illumination method for detection enables the system size to be reduced compared to systems using a typical illumination method. Furthermore, the results of a PCR test are strongly affected by the reaction temperature. Thus, extremely precise control of the temperature of the reaction is needed to obtain accurate results and good reliability. We derived a temperature compensation coefficient that allows us to compensate for the differences between the measured temperature of the negative temperature coefficient (NTC) thermistor sensor and the real temperature of the thermocouple.ResultsApplying the temperature compensation coefficient parameter using the NTC thermistor and using the side-illumination method resulted in an increase in the initial sensor value. The occurrence of the DNA section amplification decreased to 22 cycles from 24 cycles.ConclusionsThe proposed system showed comparable performance to that of an existing real-time PCR, even with the use of simpler and smaller optical devices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据