关键词

Thermostatic loads; Occupant-building interaction; Smart zoning; Adaptive optimization; Self-tuning

资金

  1. European Commission [FP7-ICT-2013.3.4, 611538]
  2. joint Project TU Delft - Xi'an Jiaotong University NEUROCON: Adaptive Neural Control for Uncertain Nonlinear Systems

向作者/读者索取更多资源

Load management actions in large buildings are pre-programmed by field engineers/users in the form of if-then else rules for the set point of the thermostat. This fixed set of actions prevents smart zoning, i.e. to dynamically regulate the set points in every room at different levels according to geometry, orientation and interaction among rooms caused by occupancy patterns. In this work we frame the problem of load management with smart zoning into a multiple-mode feedback-based optimal control problem: multiple-mode refers to embedding multiple behaviors (triggered by building-occupant dynamic interaction) into the optimization problem; feedback-based refers to adopting a Hamilton-Jacobi-Bellman framework, with closed-loop control strategies using information stemming from building and weather states. The framework is solved by parameterizing the candidate control strategies and by searching for the optimal strategy in an adaptive self-tuning way. To demonstrate the proposed approach, we employ an EnergyPlus model of an actual office building in Crete, Greece. Extensive tests show that the proposed solution is able to provide, dynamically and autonomously, dedicated set points levels in every room in such a way to optimize the whole building performance (exploitation of renewable energy sources with improved thermal comfort). As compared to pre-programmed (non-optimal) strategies, we show that smart zoning makes it is possible to save more than 15% energy consumption, with 25% increased thermal comfort. As compared to optimized strategies in which smart zoning is not implemented, smart zoning leads to additional 4% reduced energy and 8% improved comfort, demonstrating improved occupant-building interaction. Such improvements are motivated by the fact that the approach exploits the building dynamics as learned from feedback data. Moreover, the closed-loop feature of the approach makes it robust to variable weather conditions and occupancy schedules.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据